Re: Installation issue "Requires: /opt/zenoss/bin/python2.7"
Thanks Sandeep. I was able to get the rest of the install after I was able to provide the package. Much appreciation, Jacob
View ArticleRe: Zensyslog for 3com switches issue
I think you are better of using snmp traps for this. However, if you insist on using syslog, you can use rsyslog or syslog-ng on the default syslog port and zensyslog on another port (eg. syslogport...
View ArticleRe: Zensyslog for 3com switches issue
Do you know how can i configure rsyslog for doing that?? The only experience i have is configure to accept incoming logs and destination files.. But never for rewriting ... thanks!
View ArticleRe: Zensyslog for 3com switches issue
I'd have to trial and error myself... maybe you have to use an external script to parse the message and forward it to zensyslog, like in http://www.rsyslog.com/doc/omprog.html .syslog-ng offers...
View ArticleRe: Zensyslog for 3com switches issue
Hi Rob! Taking this event as example:Dec 02 15:34:04 2013 hub-pila-0005 %%10SHELL/5/CMD(l):- 1 -task:vt0 ip:10.223.168.132 user:sistemas command:display ver So..%%10SHELL/5/CMD(l):...
View ArticleRe: Zensyslog for 3com switches issue
So are you wanting to just strip the unit id out so you are left with the component and...
View ArticleRe: Zensyslog for 3com switches issue
That´s actually what i need to do!!! Great! I need to strip the unit id, where should i use ^\w{3}\s\d{1,2}\s\d{1,2}:\d\d:\d\d\s\d{4}\s(?:.*\%%)(?P<component>.*?:)(?:-.*?-)(?P<summary>.*)...
View ArticleRe: Zensyslog for 3com switches issue
Would backup your /opt/zenoss/Products/ZenEvents/SyslogProcessing.py file.Then modify after line:# generic markr"^(?P<summary>-- (?P<eventClassKey>MARK) --)", and add:# Edgardo 3Com...
View ArticleRe: Zensyslog for 3com switches issue
It makes sense but doesn´t work This is how the event keeps showing..I also restarted all zenoss daemons.. Resource:hub-cf50-09f1Component:Event Class:/UnknownStatus:NewMessage:2013 hub-cf50-09f1...
View ArticleRe: Zensyslog for 3com switches issue
Edgardo,Doesn't look like your syslog message contains the dec 02 x:x:x like expected from the syslog regex:Dec 02 15:34:04 2013 hub-pila-0005 %%10SHELL/5/CMD(l):- 1 -task:vt0 ip:10.223.168.132...
View ArticleRe: Zensyslog for 3com switches issue
You rock!! That works great!! Now, do you think there is a way to address this by using a transform?? My point is that if i keep this file modified, i need to keep in mind this mod for future zenpacks...
View ArticleRe: Zensyslog for 3com switches issue
Understand your concern. You might be able to reach our to someone like James Pulver (jmp242) on the forum about getting a parser added to future release for 3com. Think they would want more samples...
View ArticleRe: Zensyslog for 3com switches issue
Yes, by adding this regex now i will be able to reclassify these events as the they have a component. I said that i wanted to use a transform instead of editing this file because of future releases or...
View ArticleRe: Trying to install the zenpack "HTTP Components"
Do you actually have the file: /opt/zenoss/ZenPacks/ZenPacks.community.ConstructionKit-2.0.egg/ZenPacks/community/ConstructionKit/CustomProperty.py on your file system? Joseph
View Articlelocalhost zenperfsnmp heartbeat failure
Hi, I am using zenoss 3.2.1 on Ubuntu 12 platform, Its working fine since long time but i have receving subjected errors since yesterday. I have restarted Zenoss Server and its services as well but...
View ArticleTransform doesn't work on DeviceGroups field
Hi,I receive events from my python script using zensendevent and try to use transform to add DeviceGroups field but it doesn't work. My transform is simple: if...
View ArticleTimezone in timestamps
Hi I'm building a tool to get events from zenoss (via the Rest API) using the zenoss_client ruby library, however I have noticed that the timestamps returned from zenoss (ie. firstTime and lastTime)...
View ArticleRe: Transform doesn't work on DeviceGroups field
Tommy,Not sure DeviceGroups is something that you can set like you do summary for an event. A device group is a structure that the device sits in. This would be the same problem you would have if you...
View ArticleRe: Transform doesn't work on DeviceGroups field
Well, right after i sent that reply, I came across this discussion. Seems if you want to actually join a device to a group in a transform, it is definately an option:...
View ArticleRe: Transform doesn't work on DeviceGroups field
Rob,Thanks for the reply. I don't know if you understand me as well as I would like. My english is a little poor (google translator is my friend ) This is only an example:if...
View Article